Steam Sterilizers for Surgical Instruments and Medical Loads

SKsurgitech steam sterilization equipment is designed for surgical instrument processing and other applicable medical loads. The range includes horizontal pressure steam sterilizers for higher-capacity processing and compact tabletop steam sterilizers for smaller instrument loads. Different chamber capacities, sterilization temperatures, safety functions and control configurations are available to support reliable instrument sterilization workflows.

Pressure Steam
Sterilization
Multiple Capacity
Options
Safety Protection
Systems
Intelligent Control
& Easy Operation
High-Capacity Solution

Horizontal Steam Sterilizer

Designed for higher-capacity steam sterilization of surgical instruments, medical fabric items and other applicable loads. The SDL-D0313 combines multiple chamber capacities with automated sterilization, drying and integrated safety protection for demanding instrument processing requirements.

Multiple chamber capacities: 150L, 200L, 280L, 400L and 500L
Automated sterilization process with integrated drying function
Safety interlock system helps prevent operation when the chamber door is not securely closed
Over-temperature, over-pressure, water-level and overcurrent protection for safer sterilization operation
Compact Solution

Tabletop Steam Sterilizer

Compact steam sterilization for surgical and medical instruments, including applicable sealed, unsealed, hollow, non-hollow and porous loads. The SDL-D0450 combines a 23L chamber with selectable sterilization temperatures, integrated record storage and convenient data management for instrument processing workflows.

23L chamber capacity for compact instrument sterilization requirements
121°C / 134°C sterilization temperatures for different applicable instrument loads
10,000+ sterilization records with USB data export for record-keeping and management
Built-in printer for automatic sterilization data report generation after each cycle

Our Steam Sterilizer Products

Compact 23L tabletop steam sterilizer designed for surgical instruments and other compatible medical loads. Featuring 121°C / 134°C sterilization, intelligent control, dual safety door locking, cycle record storage, USB data export and a built-in printer, the SDL-D0450 supports efficient sterilization and traceable instrument processing workflows.
sksurgitech SDL-D0313 Horizontal Cylindrical Pressure Steam Sterilizer
SDL-D0313 is a high-capacity horizontal pressure steam sterilizer designed for surgical instrument processing and other compatible medical loads. With 150L–500L chamber options, automatic sterilization, drying and multiple safety protection functions, it supports reliable steam sterilization workflows for reusable instruments and medical fabric items.

Horizontal vs Tabletop Steam Sterilizer

Selection Guide Comparison Item Higher-Capacity Configuration Horizontal Steam Sterilizer SDL-D0313 Compact Configuration Tabletop Steam Sterilizer SDL-D0450
Product Type Horizontal Cylindrical Pressure Steam Sterilizer Tabletop Steam Sterilizer
Chamber Capacity 150L 200L 280L 400L 500L 23L
Sterilization Temperature 134°C 121°C 134°C
Configuration Floor-standing horizontal chamber configuration Compact tabletop configuration
Applicable Loads Surgical instruments, medical fabric items and apparatus Applicable sealed, unsealed, hollow, non-hollow and porous instruments
Sterilization Process Automated sterilization with integrated drying function High-temperature, high-pressure steam sterilization
Safety & Control Safety interlock, over-temperature, over-pressure, water-level and overcurrent protection Intelligent control system with dual mechanical and electronic door locking
Data Management Not specified in current product data 10,000+ sterilization records
USB data export and built-in printer
Best Fit Higher-capacity instrument and medical load processing Compact instrument sterilization with cycle traceability

How Pressure Steam Sterilization Works

01

Steam Generation

High-temperature steam is introduced into the sterilization chamber to begin the pressure steam sterilization process.

02

Air Removal

Air is displaced or removed from the chamber so steam can contact the applicable instrument and medical loads more effectively.

03

Sterilization

High-temperature, high-pressure steam transfers heat to the load during the selected sterilization cycle.

04

Drying & Completion

After sterilization, the cycle is completed and applicable models can support drying before processed items are removed.

Both SKsurgitech steam sterilizer models use high-temperature, high-pressure steam to support reliable sterilization of applicable surgical instruments, medical instruments and other compatible loads.

During the sterilization cycle, steam conditions inside the chamber are controlled according to the selected operating parameters to help maintain the required sterilization temperature and support consistent processing results.

Steam Sterilization Applications

Surgical Instruments

Suitable for steam sterilization of applicable reusable surgical instruments used in surgical and perioperative instrument processing workflows.

Hollow Instruments

Steam sterilization for applicable hollow and non-hollow medical instruments, supporting effective instrument processing with high-temperature, high-pressure steam.

Porous Loads

Pressure steam sterilization for applicable porous loads, supporting effective steam penetration throughout compatible medical and instrument-processing materials.

Fabric & Medical Items

Steam sterilization for applicable medical textiles, fabric items and compatible reusable materials used in surgical instrument processing and medical environments.

How to Choose a Steam Sterilizer

01
Chamber Capacity
Choose 23L tabletop or higher-capacity horizontal sterilizers based on daily workload and instrument volume.
02
Instrument Type
Consider solid, hollow, porous or fabric loads to select the appropriate sterilizer configuration.
03
Sterilization Temperature
Select 121°C or 134°C according to the compatible load and processing requirements.
04
Processing Volume
Evaluate daily sterilization volume to match chamber capacity and workflow requirements.
05
Data Traceability
For cycle record management, consider models with data storage, USB export and printing functions.

Our team is ready to help you select the most suitable steam sterilizer for your application.

ติดต่อเรา

Key Features

Stainless Steel Chamber

Stainless steel chamber construction supports durability, hygiene and corrosion resistance during repeated sterilization cycles.

Safety Protection

Safety functions vary by model and can include door interlock, over-temperature, over-pressure and electrical protection.

Automatic Control

Automated control supports programmed sterilization cycles and helps simplify routine operating procedures.

Drying Function

Applicable models support post-sterilization drying to help prepare processed loads for subsequent handling.

Data & Records (SDL-D0450)

SDL-D0450 supports 10,000+ sterilization records, USB data export and a built-in printer for cycle traceability.

คำถามที่พบบ่อย

What is a steam sterilizer?

A steam sterilizer uses high-temperature, high-pressure steam to process compatible medical instruments and other applicable loads. The required cycle depends on the sterilizer configuration, load type and operating parameters.

Which steam sterilizer is suitable for surgical instruments?

The appropriate model depends on instrument type, chamber capacity and daily processing volume. Compact instrument loads may suit a tabletop steam sterilizer, while larger workloads may require a higher-capacity horizontal steam sterilizer.

What types of steam sterilizers does SKsurgitech offer?

The current SKsurgitech range includes a horizontal cylindrical pressure steam sterilizer for higher-capacity processing and a compact tabletop steam sterilizer for smaller instrument loads.

What chamber capacity should I choose for a steam sterilizer?

Chamber capacity should be selected according to instrument volume, batch size and daily workload. The current range includes a 23L tabletop configuration and horizontal models with chamber capacities from 150L to 500L.

What is the difference between a tabletop and horizontal steam sterilizer?

A tabletop steam sterilizer is designed for more compact instrument processing, while a horizontal steam sterilizer provides larger chamber capacity for higher-volume sterilization requirements.

Does a steam sterilizer support sterilization records and data export?

Data functions vary by model. The SDL-D0450 supports more than 10,000 sterilization records, USB data export and a built-in printer for cycle record management.

Shopping Basket
下载单品彩页

Include your requirements (products, quantity, shipping, and timeline) so we can reply quickly with the right solution.

Also can click export@sksurgitech.com to submit attachments and requests.

Choose your preferred language version.

SDL-D0450 Tabletop Steam Sterilizer

单品询盘

To receive a quicker and more accurate reply, please specify your needs

(e.g., products, quantity, logistics, and delivery schedule)

Also can click export@sksurgitech.com to submit attachments and requests.