Fournir des solutions chirurgicales à l'échelle mondiale
Steam Sterilizers for Surgical Instruments and Medical Loads
SKsurgitech steam sterilization equipment is designed for surgical instrument processing and other applicable medical loads. The range includes horizontal pressure steam sterilizers for higher-capacity processing and compact tabletop steam sterilizers for smaller instrument loads. Different chamber capacities, sterilization temperatures, safety functions and control configurations are available to support reliable instrument sterilization workflows.
Designed for higher-capacity steam sterilization of surgical instruments, medical fabric items and other applicable loads. The SDL-D0313 combines multiple chamber capacities with automated sterilization, drying and integrated safety protection for demanding instrument processing requirements.
Compact steam sterilization for surgical and medical instruments, including applicable sealed, unsealed, hollow, non-hollow and porous loads. The SDL-D0450 combines a 23L chamber with selectable sterilization temperatures, integrated record storage and convenient data management for instrument processing workflows.
| Selection Guide Comparison Item | Higher-Capacity Configuration Horizontal Steam Sterilizer SDL-D0313 | Compact Configuration Tabletop Steam Sterilizer SDL-D0450 |
|---|---|---|
| Product Type | Horizontal Cylindrical Pressure Steam Sterilizer | Tabletop Steam Sterilizer |
| Chamber Capacity | 150L 200L 280L 400L 500L | 23L |
| Sterilization Temperature | 134°C | 121°C 134°C |
| Configuration | Floor-standing horizontal chamber configuration | Compact tabletop configuration |
| Applicable Loads | Surgical instruments, medical fabric items and apparatus | Applicable sealed, unsealed, hollow, non-hollow and porous instruments |
| Sterilization Process | Automated sterilization with integrated drying function | High-temperature, high-pressure steam sterilization |
| Safety & Control | Safety interlock, over-temperature, over-pressure, water-level and overcurrent protection | Intelligent control system with dual mechanical and electronic door locking |
| Data Management | Not specified in current product data |
10,000+ sterilization records
USB data export and built-in printer |
| Best Fit | Higher-capacity instrument and medical load processing | Compact instrument sterilization with cycle traceability |
High-temperature steam is introduced into the sterilization chamber to begin the pressure steam sterilization process.
Air is displaced or removed from the chamber so steam can contact the applicable instrument and medical loads more effectively.
High-temperature, high-pressure steam transfers heat to the load during the selected sterilization cycle.
After sterilization, the cycle is completed and applicable models can support drying before processed items are removed.
Both SKsurgitech steam sterilizer models use high-temperature, high-pressure steam to support reliable sterilization of applicable surgical instruments, medical instruments and other compatible loads.
During the sterilization cycle, steam conditions inside the chamber are controlled according to the selected operating parameters to help maintain the required sterilization temperature and support consistent processing results.
Suitable for steam sterilization of applicable reusable surgical instruments used in surgical and perioperative instrument processing workflows.
Steam sterilization for applicable hollow and non-hollow medical instruments, supporting effective instrument processing with high-temperature, high-pressure steam.
Pressure steam sterilization for applicable porous loads, supporting effective steam penetration throughout compatible medical and instrument-processing materials.
Steam sterilization for applicable medical textiles, fabric items and compatible reusable materials used in surgical instrument processing and medical environments.
Our team is ready to help you select the most suitable steam sterilizer for your application.
Contactez-nousStainless steel chamber construction supports durability, hygiene and corrosion resistance during repeated sterilization cycles.
Safety functions vary by model and can include door interlock, over-temperature, over-pressure and electrical protection.
Automated control supports programmed sterilization cycles and helps simplify routine operating procedures.
Applicable models support post-sterilization drying to help prepare processed loads for subsequent handling.
SDL-D0450 supports 10,000+ sterilization records, USB data export and a built-in printer for cycle traceability.
A steam sterilizer uses high-temperature, high-pressure steam to process compatible medical instruments and other applicable loads. The required cycle depends on the sterilizer configuration, load type and operating parameters.
The appropriate model depends on instrument type, chamber capacity and daily processing volume. Compact instrument loads may suit a tabletop steam sterilizer, while larger workloads may require a higher-capacity horizontal steam sterilizer.
The current SKsurgitech range includes a horizontal cylindrical pressure steam sterilizer for higher-capacity processing and a compact tabletop steam sterilizer for smaller instrument loads.
Chamber capacity should be selected according to instrument volume, batch size and daily workload. The current range includes a 23L tabletop configuration and horizontal models with chamber capacities from 150L to 500L.
A tabletop steam sterilizer is designed for more compact instrument processing, while a horizontal steam sterilizer provides larger chamber capacity for higher-volume sterilization requirements.
Data functions vary by model. The SDL-D0450 supports more than 10,000 sterilization records, USB data export and a built-in printer for cycle record management.
Choisissez votre version linguistique préférée.
SDL-D0450 Tabletop Steam Sterilizer